Air-to-Water · R290 · Hydraulic
The Panasonic Aquarea Hydraulic is an R290 air-to-water heat pump for whole-home heating and domestic hot water. The refrigerant stays in the outdoor unit. Only water pipes run into the house, so the installation is the same idea as a monobloc: an outdoor unit, a cylinder or hydrobox indoors, and the existing radiators or underfloor heating.
It can deliver water at up to 75°C in suitable conditions. The correct output, from 5 kW to 16 kW for a house, is chosen from a room-by-room heat-loss calculation, not from the existing boiler size.
The photograph and the specification sheet are Panasonic’s High Performance L series 5 kW bi-bloc: outdoor unit WH-WDG05LE5 with wall-hung indoor unit WH-SDC0509L3E5.
Survey and heat loss decide which family, and which size. Both are R290 and both connect to the house with water.
The range for a typical house. L series is 5, 7 and 9 kW, single phase, with 75°C water available down to -10°C outside and heating operation down to -25°C. Sound power is about 52, 53 and 54 dB(A) for the 5, 7 and 9 kW units. M series extends this to 12 and 16 kW on single phase, and 9, 12 and 16 kW on three phase, with 75°C water down to -15°C outside. Panasonic marks some M-series outdoor figures as tentative, including WH-WDG12ME5 and WH-WDG16ME5, so those are not treated here as final tested data.
The cold-weather range. Output is maintained at a 55°C water temperature down to -15°C outside, and the 9–16 kW models heat down to -28°C. Single phase at 9 and 12 kW. Three phase at 9, 12 and 16 kW. This is the closer match where the design needs high radiator temperatures in cold weather.
Larger T-CAP outdoor units at 20, 25 and 30 kW are three phase only and are aimed at big houses or central plant. They are not the usual selection for the homes on this page. On these units, 75°C water is only down to 15°C outside, not -15°C.
| Outdoor model | Output | Phase | Family |
|---|---|---|---|
| WH-WDG05LE5 | 5 kW | Single | High Performance L |
| WH-WDG07LE5 | 7 kW | Single | High Performance L |
| WH-WDG09LE5 | 9 kW | Single | High Performance L |
| WH-WDG12ME5 | 12 kW | Single | High Performance M |
| WH-WDG16ME5 | 16 kW | Single | High Performance M |
| WH-WDG09ME8 | 9 kW | Three | High Performance M |
| WH-WDG12ME8 | 12 kW | Three | High Performance M |
| WH-WDG16ME8 | 16 kW | Three | High Performance M |
| WH-WXG09ME5 | 9 kW | Single | T-CAP M |
| WH-WXG12ME5 | 12 kW | Single | T-CAP M |
| WH-WXG09ME8 | 9 kW | Three | T-CAP M |
| WH-WXG12ME8 | 12 kW | Three | T-CAP M |
| WH-WXG16ME8 | 16 kW | Three | T-CAP M |
E5 in a model code is single phase. E8 is three phase.
Four ways to connect the outdoor unit. The all-in-one and the hydrobox are the two used most often in a house.
Floor-standing cylinder with the hydraulic controls in one cabinet. Footprint 599 × 602 mm. L series: 120 or 185 litres. M series: 120, 185 or 260 litres. Panasonic includes the G3 unvented kit with the all-in-one. A 3 kW backup heater is built in. There is no 260-litre all-in-one on the L series.
A wall-hung indoor unit with a 3 kW backup heater on single phase, or 9 kW on three phase. The cylinder is separate. Still a water connection, not a refrigerant pipe into the house.
A small controller where the cylinder and pumps are arranged on site. Single phase uses WH-CME5. Three phase uses WH-CME8.
The outdoor unit with a separate cylinder and the Panasonic remote controller CZ-RTW2TAW1C. Closest to a monobloc plus a cylinder from another range, confirmed on survey.
An initial guide only. Final specification depends on heat loss, hot-water demand, radiator output, pipework, electrical supply and space.
| Your home | Option to investigate |
|---|---|
| Smaller house, single phase | High Performance L, 5–9 kW |
| Typical family hot-water use | All in One, 185 litres |
| Larger hot-water demand or more than one bathroom | All in One, 260 litres, on an M-series outdoor unit |
| Limited floor space, or an existing cylinder that may be kept | Bi-bloc hydrobox, subject to coil and recovery checks |
| Radiators you hope to keep, including in cold weather | T-CAP, subject to radiator output at the design flow temperature |
| Three-phase supply, larger heat loss | High Performance M or T-CAP M, 9–16 kW three phase |
| Underfloor heating | Either family, usually at a lower flow temperature |
| Solar PV planned or already installed | Either family, subject to controls and the electrical design |
An existing cylinder is not assumed to be suitable. The survey checks coil area, volume, insulation, sensors, immersion and the safety set. Radiators and underfloor circuits are checked at the proposed flow temperature. Some rooms may need larger radiators so the heat pump can run efficiently.
On the L-series all-in-one the catalogue shows the electrical supply at the indoor unit, with two single-phase circuits listed at 25 A and 16 A. The exact arrangement is confirmed from the installation manual for the selected model.
The exact equipment list is confirmed in the survey and quotation.
Before recommending a system, we review whether Aquarea Hydraulic — High Performance or T-CAP, and which indoor arrangement — is appropriate for your home.
Considering an Aquarea Hydraulic system? Tell
Current about your home, heating system and hot-water needs. Output, High Performance or T-CAP, and the indoor arrangement are confirmed after survey. There is no online checkout and no price on this page.
This page covers Panasonic’s R290 Aquarea Hydraulic range only. R32 Aquarea models are not offered. Availability, model numbers and specifications should be confirmed for each project. A recommendation needs a qualified survey, heat-loss calculation, radiator and pipework assessment, hot-water assessment, and confirmation of the electrical supply. R290 systems are installed by appropriately qualified personnel.