  3. ·Air-to-Water heat pump
  4. ·Panasonic Aquarea Hydraulic
Panasonic Aquarea Hydraulic L series: wall-hung indoor unit and outdoor unit

Air-to-Water · R290 · Hydraulic

Panasonic Aquarea Hydraulic

The Panasonic Aquarea Hydraulic is an R290 air-to-water heat pump for whole-home heating and domestic hot water. The refrigerant stays in the outdoor unit. Only water pipes run into the house, so the installation is the same idea as a monobloc: an outdoor unit, a cylinder or hydrobox indoors, and the existing radiators or underfloor heating.

It can deliver water at up to 75°C in suitable conditions. The correct output, from 5 kW to 16 kW for a house, is chosen from a room-by-room heat-loss calculation, not from the existing boiler size.

The photograph and the specification sheet are Panasonic’s High Performance L series 5 kW bi-bloc: outdoor unit WH-WDG05LE5 with wall-hung indoor unit WH-SDC0509L3E5.

L series 5 kW specification sheet (PDF)

Features

  • R290 natural refrigerant with very low global-warming potential.
  • Refrigerant circuit stays outdoors. The house connection is water only.
  • Water temperatures up to 75°C, for radiator retrofit where the survey supports it.
  • Heating and domestic hot water in one system.
  • High Performance models from 5 kW to 16 kW, single phase and three phase.
  • T-CAP models that hold heating capacity as the outdoor temperature falls, down to -28°C operation on the 9–16 kW T-CAP range.
  • All-in-one cylinder, wall-hung hydrobox, or a separate cylinder.
  • Wi-Fi control through the Panasonic Comfort Cloud app. The adaptor is included.

Why consider Aquarea Hydraulic?

  • R290, with the refrigerant kept outside the home.
  • Water at up to 75°C, so many existing radiator systems can be assessed rather than assumed to need replacement.
  • A quieter High Performance L series for smaller homes: the 5 kW unit is 27 dB(A) sound pressure at 5 m in quiet mode.
  • All-in-one cylinders at 120, 185 or 260 litres, with the G3 unvented kit included in Panasonic’s all-in-one package.
  • A wall-hung hydrobox where a separate cylinder is preferred.
  • T-CAP where the heat pump has to keep its output in colder weather, rather than leaning on the backup heater.
  • Single phase for the usual house sizes, and three phase from 9 kW upwards.
  • Heating operation down to -25°C on High Performance, and -28°C on T-CAP 9–16 kW.

Two outdoor families

Survey and heat loss decide which family, and which size. Both are R290 and both connect to the house with water.

High Performance

The range for a typical house. L series is 5, 7 and 9 kW, single phase, with 75°C water available down to -10°C outside and heating operation down to -25°C. Sound power is about 52, 53 and 54 dB(A) for the 5, 7 and 9 kW units. M series extends this to 12 and 16 kW on single phase, and 9, 12 and 16 kW on three phase, with 75°C water down to -15°C outside. Panasonic marks some M-series outdoor figures as tentative, including WH-WDG12ME5 and WH-WDG16ME5, so those are not treated here as final tested data.

T-CAP

The cold-weather range. Output is maintained at a 55°C water temperature down to -15°C outside, and the 9–16 kW models heat down to -28°C. Single phase at 9 and 12 kW. Three phase at 9, 12 and 16 kW. This is the closer match where the design needs high radiator temperatures in cold weather.

Larger T-CAP outdoor units at 20, 25 and 30 kW are three phase only and are aimed at big houses or central plant. They are not the usual selection for the homes on this page. On these units, 75°C water is only down to 15°C outside, not -15°C.

Outdoor modelOutputPhaseFamily
WH-WDG05LE55 kWSingleHigh Performance L
WH-WDG07LE57 kWSingleHigh Performance L
WH-WDG09LE59 kWSingleHigh Performance L
WH-WDG12ME512 kWSingleHigh Performance M
WH-WDG16ME516 kWSingleHigh Performance M
WH-WDG09ME89 kWThreeHigh Performance M
WH-WDG12ME812 kWThreeHigh Performance M
WH-WDG16ME816 kWThreeHigh Performance M
WH-WXG09ME59 kWSingleT-CAP M
WH-WXG12ME512 kWSingleT-CAP M
WH-WXG09ME89 kWThreeT-CAP M
WH-WXG12ME812 kWThreeT-CAP M
WH-WXG16ME816 kWThreeT-CAP M

E5 in a model code is single phase. E8 is three phase.

Indoor arrangements

Four ways to connect the outdoor unit. The all-in-one and the hydrobox are the two used most often in a house.

All in One

Floor-standing cylinder with the hydraulic controls in one cabinet. Footprint 599 × 602 mm. L series: 120 or 185 litres. M series: 120, 185 or 260 litres. Panasonic includes the G3 unvented kit with the all-in-one. A 3 kW backup heater is built in. There is no 260-litre all-in-one on the L series.

Bi-bloc hydrobox

A wall-hung indoor unit with a 3 kW backup heater on single phase, or 9 kW on three phase. The cylinder is separate. Still a water connection, not a refrigerant pipe into the house.

Control module

A small controller where the cylinder and pumps are arranged on site. Single phase uses WH-CME5. Three phase uses WH-CME8.

Stand-alone outdoor unit

The outdoor unit with a separate cylinder and the Panasonic remote controller CZ-RTW2TAW1C. Closest to a monobloc plus a cylinder from another range, confirmed on survey.

Which arrangement may suit you?

An initial guide only. Final specification depends on heat loss, hot-water demand, radiator output, pipework, electrical supply and space.

Your homeOption to investigate
Smaller house, single phaseHigh Performance L, 5–9 kW
Typical family hot-water useAll in One, 185 litres
Larger hot-water demand or more than one bathroomAll in One, 260 litres, on an M-series outdoor unit
Limited floor space, or an existing cylinder that may be keptBi-bloc hydrobox, subject to coil and recovery checks
Radiators you hope to keep, including in cold weatherT-CAP, subject to radiator output at the design flow temperature
Three-phase supply, larger heat lossHigh Performance M or T-CAP M, 9–16 kW three phase
Underfloor heatingEither family, usually at a lower flow temperature
Solar PV planned or already installedEither family, subject to controls and the electrical design

Existing cylinders, radiators and supply

An existing cylinder is not assumed to be suitable. The survey checks coil area, volume, insulation, sensors, immersion and the safety set. Radiators and underfloor circuits are checked at the proposed flow temperature. Some rooms may need larger radiators so the heat pump can run efficiently.

On the L-series all-in-one the catalogue shows the electrical supply at the indoor unit, with two single-phase circuits listed at 25 A and 16 A. The exact arrangement is confirmed from the installation manual for the selected model.

A complete Aquarea Hydraulic system may include

  • Panasonic Aquarea Hydraulic outdoor unit.
  • All-in-one cylinder, or a hydrobox plus cylinder.
  • Backup heater, pumps, valves and sensors.
  • G3 unvented kit on an all-in-one.
  • Weather-compensating controls and the Comfort Cloud adaptor.
  • Radiator or underfloor modifications.
  • Insulated external water pipework and frost protection.
  • Electrical isolators and protection.
  • Solar PV or smart-grid interface, where planned.

The exact equipment list is confirmed in the survey and quotation.

What Pretium Synergy will assess

Before recommending a system, we review whether Aquarea Hydraulic — High Performance or T-CAP, and which indoor arrangement — is appropriate for your home.

  • Property size and construction, and room-by-room heat loss.
  • Existing boiler, controls, radiators, pipework and circulation.
  • Existing hot-water cylinder and required capacity.
  • Outdoor-unit position, noise and clearances.
  • Electrical supply.
  • Solar PV, battery and EV-charging plans.
  • Planning, building-regulation and installation requirements.

Register interest

Considering an Aquarea Hydraulic system? Tell Current about your home, heating system and hot-water needs. Output, High Performance or T-CAP, and the indoor arrangement are confirmed after survey. There is no online checkout and no price on this page.

This page covers Panasonic’s R290 Aquarea Hydraulic range only. R32 Aquarea models are not offered. Availability, model numbers and specifications should be confirmed for each project. A recommendation needs a qualified survey, heat-loss calculation, radiator and pipework assessment, hot-water assessment, and confirmation of the electrical supply. R290 systems are installed by appropriately qualified personnel.

  • OZEV
  • ★Trustpilot|Rated Excellent
  • Stripe ClimateStripe Climate Contribution

For your home

  • Air conditioning
  • Heat pumps
  • Solar and batteries
  • EV charging
  • Plan the whole home
  • Newsletter

For your business

  • Commercial energy services
  • Charging for sites and fleets
  • Off-grid power
  • Commercial Insights

Help & advice

  • Contact us
  • Request a callback
  • FAQs
  • Customer login
  • Installation & warranty terms
  • customer.service@pretiumsynergy.co.uk

About Pretium

  • About us
  • Why Pretium
  • Pretium Team
  • Installation partners
  • Customer reviews

© 2026 Pretium Synergy Ltd

Company detailsPrivacy policyWebsite terms